Emergency LED

Guide & Flood lighting

Emergency maintained and non-maintained fittings

Positioning at points of emphasis

Introducing the SIGHT range
Emergency lighting is mandatory in offices, schools, public buildings/spaces, and some private dwellings for them to meet fire safety legislation and all building regulations. Emergency lights are required for escape routes, open spaces and in high risk areas. All schemes must be approved by the relevant authorities. Emergency lighting is compulsory in the specific areas below.
In these areas, the minimum illuminance level that must be achieved is 1 lux. Below we have highlighted on the diagram where lighting is required when the mains power is lost. These products in our new Sight range cover each of these required applications.
Sight_main image3

Viewing Signage & Distances

Where lighting is used for emergency escape routes it must be used in conjunction with clear and unambiguous signs. BS 5266 defines a code of practice and principles for the emergency escape lighting of premises. There are a number of different sign standards that have been used in the past, but for new properties it is recommended that ISO 7010 signs are used. It is not permitted to mix different styles of emergency exit signs so a number of our fittings are supplied with both the ISO 7010 and BS 5499 signs allowing you to use them in new buildings or for retrofitting to older buildings.

ISO 7010_2 column
ISO 7010
BS 5499_2 column
BS 5499
Viewing distances for our Sight range

Product code

Description

Viewing Distance

72636 Sight Plus 16m
72637 Sight Plus 16m
72639 Sight Plus Wedge 22m
72640 Sight Eco 16m
72644 Sight 4-IN-1 28m
72696 Sight Box 38m
Internally illuminated signs
Internal signs_2 column
Externally illuminated signs
External signs_2 column

Viewing distances are specified in BS EN 1838 as 200 x Height of the pictogram for internally Illuminated signs, and 100 x Height of the pictogram for externally illuminated signs


Sight Box

The Sight Box is our maintained wall mounted emergency light, suitable for all applications where clear signage is required in retail and commercial environments. It has two conduit entry points for flexible fitting and is supplied with all the ISO 7010 directional signs. The 1.5W LEDs provides 3 hours of light to illuminate the sign when power is lost

Box_icons
Complete with integrated control gear
1.5W LED module (SMD 2835) Daylight White (Included)
38m viewing distance
Complete with fixing accessories
Gloss white & green polycarbonate
Box_2 column

Sight 4-IN-1

The Sight 4-in-1 is a multi functional maintained LED emergency guide fitting. It can be ceiling mounted in two positions, suspended and recessed, it can also be fitted to a wall from either side or the back. The 1W LEDs provide 3 hours of light to illuminate the sign when power is lost

4 in 1_icons
Complete with integrated control gear
1W LED module (SMD 3014) Daylight White (Included)
28m viewing distance
Adjustable height
Complete with fixing accessories
Gloss white & green polycarbonate
4 in 1_2 column

Sight Eco - due early 2018

Slim emergency maintained bulkhead, supplied with a self adhesive emergency sign kit. The 0.5W LED module provides up to 3 hours of light when power is lost

Eco_icons
Complete with integrated control gear
0.5W LED module (SMD 2835) Daylight White (Included)
16m viewing distance
Complete with fixing accessories
Clear prismatic & gloss white polycarbonate
Energy efficient product
Eco_2 column


Sight Plus

Reliable, robust, weatherproof and functional. The Sight Plus LED bulkhead is a maintained emergency fitting. The daylight white 2W LED module offers 136 lumens for up to 3 hours when power is lost. Supplied with a self adhesive emergency sign kit, additional fitting accessories include a wedge and recessed housing for alternative positioning

Plus_icons
Complete with integrated control gear
2W LED module (SMD 2835) Daylight White (Included)
Complete with fixing accessories
Clear prismatic & gloss white polycarbonate
Suitable for indoor or outdoor use
Recessed fitting accessory available 

Plus_2 column

Sight Recessed

Emergency maintained, LED recessed guide fitting for ceilings. The 3W LEDs provide 160 lumens for up to 3 hours when power is lost

Recessed_icons
Complete with integrated control gear
3W LED module (SMD 2835) Daylight White (Included)
Complete with fixing accessories
Gloss white steel & clear prismatic
Recessed_2 column


Sight Twin Spot

The Sight Twin Spot is a non maintained emergency LED fitting for indoor and outdoor use. Complete with a fault alarm which will beep and flash when not installed correctly. Each head is fully adjustable for angled illumination when needed. The two 3.5W HI Power LEDs provide 570 lumens for up to 3 hours when power is lost

Twin spot square_icons
Complete with integrated control gear
2 x 3W LED module (SMD 2835) Daylight White (Included)
Complete with fixing accessories
Clear & frosted polycarbonate
Twin spot square_2 column

Sight Twin Spot

The Sight Twin Spot is a non maintained emergency LED fitting for indoor and outdoor use. Complete with a fault alarm which will beep and flash when not installed correctly. Each head is fully adjustable for angled illumination when needed. The two 3.5W HI Power LEDs provide 570 lumens for up to 3 hours when power is lost

Twin spot round_icons
Complete with integrated control gear
2 x 3W LED module (SMD 2835) Daylight White (Included)
Emergency non-maintained fitting
Complete with fixing accessories
Clear & frosted polycarbonate
Twin spot round_2 column